 Recently, we received an email from a foreign customer, showing the content: "I am writing to see whether you are interested in a quotation of a waste boiler for one of our project going to be installed in China: Our customer want to install a waster heat boiler in between their exiting Incinerator and scrubber tower to recovery energy for using in the rest of their plant. "

ZBG Boiler Factory is a manufacturer of Class A waste heat boilers in China. The quotation of waste heat boilers needs to be determined according to the parameters of the designed waste heat boilers. All waste heat boilers are customized and cannot be mass-produced.

www.zgindustrialboiler.com/product/waste-heat-boiler/waste heat boilers.jpg

waste heat boilers

SCOPE OF SUPPLY

One (1) only – waste heat boiler (better fire tube type, China local standard)

Feed water Inlet temperature is 105°C The maximum upset temperature of gases for design purposes is 1100°C The min. steam output will be medium pressure 13 barg @ 28T/hr, 195°C The steam condensate will be delivered at pressure to our boiler system. We prefer to keep gas side pressure drop to below 120mm H2O Accessories: Safety valve, Level Gauge, Sample Cooler.

(b) Tagging of all equipment. Tagging shall consist of Vendor's standard stainless-steel nameplate (approx. 4" x 6") permanently affixed to the equipment. The engraved nameplate shall display the name of the equipment, purchaser’s equipment number, purchaser’s purchase order number, and year of manufacture.

(c) All carbon steel parts to be painted per mill specification

(d) Equipment drawings with parts lists. Drawings are to show necessary details for assembly, maintenance, and operation.

(e) Installation, Startup, Operation, Lubrication, and Maintenance manuals c/w as built drawings.

(f) A recommended spare parts list with two sets of itemized pricing - one price for spares purchased with order and one price for spares purchased otherwise.

(g) Skid and boxing for transport (as applicable).

(h) 1 set of electronic documents and 6 copies of document in paper is to be provided

Technical information required with the proposal:

(a) Equipment specifications outlining:

(i) materials of construction/material thicknesses

(ii) dimension drawing with drawing scale

(iii) shipping and operating weights of equipment

(iv) noise level

(v) pressure drops

(b) A material, workmanship and performance guarantee.

5t/h Waste Heat Boiler Used in Rotary Lime Kiln Production Line Project

2023-10-26

Type Selection and Technical Parameters of Guangdong 5t/h Low Temperature and Low Pressure Waste Heat Boiler1. Flue gas waste heat conditions of the project1)

12.8t/h Sintering Machine Waste Heat Boiler Project and Its Technical Parameters

2023-10-19

320m2 sintering area of ​​iron and steel plant with 12.8 tons sintering machine waste heat boiler project1. Meteorological conditions Average temperature

The Scope of Supply of the Whole Set of Cdq Waste Heat Boiler EquipmentThe Scope of Supply of the Wh

2023-10-09

The Scope of Supply of the Whole Set of Cdq Waste Heat Boiler EquipmentThe Scope of Supply of the Whole Set of Cdq Waste Heat Boiler Equipment

Waste heat boiler quality and life

2023-09-18

The waste heat boiler shall be designed and manufactured according to the corresponding indicators of national standards and current industry standards. The s

The basic requirements of the waste heat recovery boiler body in the actual project

2023-09-07

1 The waste heat recovery boiler is built-in and installed in the large flue, the flue gas passage of the device is well sealed, and the air leakage rate is

Flue gas flow rate 160000Nm³/h waste heat boiler parameters and supply list

2023-08-31

1. Waste heat boiler flue gas parameters: serial number project unit value 1

Q=32.4t/h waste incineration waste heat boiler P=6.5MPa T=450℃

2023-08-07

Q=32.4t/h waste incineration waste heat boiler P=6.5MPa T=450℃ device name Models and Specifications

7.7t/h And 15.4 Tph Waste Heat Steam Boiler Technical Parameters

2023-08-03

Q=7.7t/h waste heat steam boiler technical parameters1. Main technical parameters: Rated evaporation: Q=7.7t/h (calculated by the boiler factory) Superhe

Analysis Of The Market Prospect Of Waste Heat Boiler Manufacturers In 2023

2023-07-31

The waste heat boiler industry is an important part of China's power generation equipment manufacturing industry, undertaking the task of providing key techn

Understand The Model Parameters Of Waste Heat Boiler In 1 Minute

2023-06-08

The waste heat boiler product model consists of two parts. The first part indicates the afterburning situation of the waste heat boiler, the type, characteris

Get An Instant Quotation

For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.


  • Heat Converters
  • Pressure Converters
  • Temperature Converters

Any question, please contact us for free. Phone number: +86-371-86167233 Whatsapp: +86 177 19888549 Email:[email protected]

KW
bar
    °C